Quick answer: Specify equipment for an operation theatre by numbers, not by names. Pendants: two arms, 160 kg load on the surgical arm, six gas outlets and twelve power sockets. Control panel: 15-inch touch screen for temperature, humidity, pressure, gas alarms and surgery time. Scrub sink: SS 304, two or three bays, sensor taps. Doors: hermetically sealed sliding, 1.5 m clear for the patient door. Pass box: interlocked, with UV. Put those figures in the tender, and every quote in the UAE then describes the same room.
Most tenders in Dubai and Abu Dhabi list the equipment for an operation theatre as names: pendant, panel, sink, door. However, a name carries no load rating, no steel grade and no outlet count. So three quotes arrive for three different products. This guide gives the numbers that make them comparable.
Pendants: the heaviest equipment for an operation theatre
Specify two pendants: anaesthesia at the head, surgery at the side. The surgical arm then needs 160 kg load, 800 mm plus 800 mm reach and brakes on every joint. The anaesthesia arm, however, needs only 120 kg. Then list the outlets: six gas terminals (oxygen, nitrous oxide, air at 4 and 7 bar, vacuum, AGSS), twelve power sockets, four data points and an equipotential bar. Finally, ask how the ceiling carries the load, because a pendant is the heaviest equipment for an operation theatre after the light.

Panels: the wall system and the OT control panel
The wall panel comes first: 50 mm thick, HPL or SS 304 skin, PUF or rock-wool core, coved corners and gasketed joints. The OT control panel then sits flush in that wall. It needs a 15-inch touch screen for temperature, humidity, differential pressure, clock and an elapsed surgery timer. It also carries the gas alarm, a HEPA pressure-drop alarm and the lighting controls. Above all, ask for spare channels, since every operation theatre adds equipment later.

Scrub sinks and the pass box
Specify the scrub sink in SS 304, 1.2 mm thick, brushed, with a 300 mm splash-back. A two-bay unit runs about 1,500 mm, while a three-bay unit runs about 2,100 mm. Each bay needs a sensor tap and a thermostatic mixer set at 38 to 40 °C. Similarly, the pass box between sterile store and theatre should be SS 304, about 450 mm cubed. It needs an interlock, so both doors never open together, plus a UV lamp with an hour meter.

Doors: the equipment for an operation theatre that moves most
A theatre door opens hundreds of times a day, so it fails first. Ask for hermetically sealed sliding doors with a drop seal, foot-sensor and elbow-switch operation, and a closing time under five seconds. The patient door needs 1.5 m clear, whereas the staff door needs 1.2 m. Specify an HPL or SS 304 leaf on a honeycomb core and a vision panel with an integral blind. Where a C-arm works, also add 2 mm lead equivalence. Also ask for the leakage figure, because the door decides whether the room holds its 10 Pa.

How Agora specifies equipment for an operation theatre
Agora Climate Control Systems issues these numbers as a one-page sheet with every quote, so hospitals compare like with like. The sheet follows the room lists in the FGI Guidelines and the DHA Health Facility Guidelines. For the built-in versus loose split, read our operation theatre equipment list, and for the Indian range see modular OT equipment manufacturers. Our guide to the modular operating theatre then covers the room itself.

Frequently asked questions
Which equipment for an operation theatre comes built in?
Pendants, OT control panel, scrub sink, X-ray viewer, hermetic doors, pass box, storage and the laminar ceiling. Tables, lights and anaesthesia machines, however, are loose items.
What load rating should a surgical pendant have?
160 kg on the surgical arm and 120 kg on the anaesthesia arm, with brakes on every joint.
Which steel grade suits a scrub sink?
SS 304 at 1.2 mm with a brushed finish, because it resists chlorine wipes and hard UAE water.
How wide should the theatre doors be?
1.5 m clear for the patient door, while the staff door needs 1.2 m; both hermetically sealed and sliding.
Who should specify equipment for an operation theatre?
The biomedical engineer with the modular supplier, before anyone approves the ceiling drawing, because plate loads and outlet positions depend on it.
Need a specification for equipment for an operation theatre?
Send us your tender list. We then return the numbered specification, the ceiling load plan and an itemised AED quote within two working days. WhatsApp +91 93232 98094 or request a free consultation at agoraccs.com/contact.